Publication:

A minimally-invasive, on-site identification method for lead-lined water service lines: A case study in Trenton, NJ

datacite.rightsrestricted
dc.contributor.advisorHiggins, John
dc.contributor.authorRodrigues, Isabel
dc.date.accessioned2023-07-06T15:08:21Z
dc.date.accessioned2026-09-29T23:02:01Z
dc.date.available2023-07-06T15:08:21Z
dc.date.available2026-09-29T23:02:01Z
dc.date.created2023-04-27
dc.date.issued2023-07-06
dc.description.abstractLead exposure is a well-understood health risk, both acutely via lead poisoning, and at low dosages for a prolonged period. Historically, lead was commonly used in many industries, including in paint, gasoline, and plumbing. In the 21st century, high-profile cases of elevated lead levels in residential tap water systems in Washington, D.C. (2003), Flint, MI (2014), and Newark, NJ (2016) made replacing lead pipes a priority for many municipalities. Replacement became particularly important for cities with large amounts of housing built before the 1986 federal lead pipe ban. However, most municipalities do not have accurate or complete records of where lead pipes were installed, particularly on the privately-owned, homeowner side of the line, and steel pipes lined with lead often go undetected by conventional identification methods. In this paper, we propose and evaluate a novel method of identifying lead-lined water service lines using a portable x-ray fluorescence (XRF) device. Using a suit of 656 samples from pipes replaced in Trenton City and Hamilton, NJ, we found that an XRF analysis on the outer surface of the pipe was capable of detecting ~70% of lead-lined samples, and that ~90% samples with an outer surface reading of at least 10,000 ppm were visibly lead-lined. This minimally invasive approach allows utilities to quickly and accurately identify lead service lines without cutting or excavation.en_US
dc.format.mimetypeapplication/pdf
dc.identifier.urihttp://arks.princeton.edu/ark:/88435/dsp01cj82kb54x
dc.identifier.urihttps://theses-dissertations.princeton.edu/handle/88435/dsp01cj82kb54x
dc.language.isoenen_US
dc.titleA minimally-invasive, on-site identification method for lead-lined water service lines: A case study in Trenton, NJen_US
dc.typePrinceton University Senior Theses
dspace.entity.typePublication
pu.certificateEnvironmental Studies Programen_US
pu.contributor.authorid920228142
pu.date.classyear2023en_US
pu.departmentGeosciencesen_US
pu.mudd.walkinNoen_US
pu.pdf.coverpageSeniorThesisCoverPage

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
RODRIGUES-ISABEL-THESIS.pdf
Size:
1.67 MB
Format:
Adobe Portable Document Format
Download

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
LICENSE.txt
Size:
253 B
Format:
Plain Text
Description:
Download